logo
محصولات
محصولات
خونه > محصولات > سیستم تصفیه آب > ST501 Water Treatment System Featuring Non Contact Clamp On Ultrasonic Flowmeter to Ensure No Downtime or Calibration Expense

ST501 Water Treatment System Featuring Non Contact Clamp On Ultrasonic Flowmeter to Ensure No Downtime or Calibration Expense

جزئیات محصول

محل منبع: شنژن، چین

نام تجاری: Flo-Instru

گواهی: CE; ISO9001

شماره مدل: ST501

شرایط پرداخت و حمل و نقل

مقدار حداقل تعداد سفارش: 1

جزئیات بسته بندی: بسته بندی معمولی

زمان تحویل: 3-5 روز کاری

شرایط پرداخت: T/T

بهترین قیمت رو بدست بیار
برجسته کردن:

ST501 water treatment system with ultrasonic flowmeter,non-contact clamp-on water treatment system,water treatment system with no downtime

,

non-contact clamp-on water treatment system

,

water treatment system with no downtime

محدوده سرعت:
0 ~ 16 ± فوت بر ثانیه (0 ~ ± 5 متر بر ثانیه)
دقت:
%1.0 ±
اندازه لوله:
1 تا 48 اینچ (25 میلی متر تا 1200 میلی متر)
مایع:
آب دریا، نفت سفید، بنزین، روغن، الکل و غیره
ماده لوله:
PVC، فولاد کربن، فولاد ضد زنگ، مس، و غیره
خروجی های اختیاری:
خروجی پالس OCT: 0~5000Hz.خروجی آنالوگ: 4~20mA، حداکثر بار 750Ω.
رابط ارتباطی:
RS485
منبع تغذیه:
24 ولت DC/1A
صفحه کلید:
کلید 16 (4×4) با عملکرد لمسی
نمایش:
20×2 شبکه الفبایی، ال سی دی با نور پشت.
دما:
فرستنده: 32℉~140℉(0℃~60℃) مبدل: 32℉~140℉(0℃~60℃)
رطوبت:
تا 99% RH، غیر متراکم
فرستنده:
آلیاژ آلومینیوم، IP65.
مبدل:
طراحی کپسوله، IP68.
کابل مبدل:
طول کابل استاندارد: 33 فوت (10 متر)
محدوده سرعت:
0 ~ 16 ± فوت بر ثانیه (0 ~ ± 5 متر بر ثانیه)
دقت:
%1.0 ±
اندازه لوله:
1 تا 48 اینچ (25 میلی متر تا 1200 میلی متر)
مایع:
آب دریا، نفت سفید، بنزین، روغن، الکل و غیره
ماده لوله:
PVC، فولاد کربن، فولاد ضد زنگ، مس، و غیره
خروجی های اختیاری:
خروجی پالس OCT: 0~5000Hz.خروجی آنالوگ: 4~20mA، حداکثر بار 750Ω.
رابط ارتباطی:
RS485
منبع تغذیه:
24 ولت DC/1A
صفحه کلید:
کلید 16 (4×4) با عملکرد لمسی
نمایش:
20×2 شبکه الفبایی، ال سی دی با نور پشت.
دما:
فرستنده: 32℉~140℉(0℃~60℃) مبدل: 32℉~140℉(0℃~60℃)
رطوبت:
تا 99% RH، غیر متراکم
فرستنده:
آلیاژ آلومینیوم، IP65.
مبدل:
طراحی کپسوله، IP68.
کابل مبدل:
طول کابل استاندارد: 33 فوت (10 متر)
ST501 Water Treatment System Featuring Non Contact Clamp On Ultrasonic Flowmeter to Ensure No Downtime or Calibration Expense

ST501 Stationary Ultrasonic Flowmeter

Integrate into your management system to provide remote measurement services.

Cost-Effective Fixed Ultrasonic Flowmeter ST501

 

Introduction

ST501 Ultrasonic flow meter uses the most reliable digital signal processing technology, transmitting flow measurement for a wide range of liquid and pipe size with high accuracy and reliability. Combined the outstanding performance transducer with higher industrial level material, Flo-Instruments can have long time work without any worries.
Clear menu display selections make use of instruments very convenient. Clamp-on transducers makes the unit more flexible over a wide range of applications.
The ST501 ultrasonic flowmeter is based on Transit-Time technology, which has high measurement accuracy. ST501 uses a clamp-on transducer, which can collect flow data simply by clamping it on the outside of the pipe, and it will never come into contact with the fluid, and will not cause liquid pollution, pressure reduction, leakage, etc.

 

 

Benefits

  • Measures the actual flow and total consumption ofvarious liquids
  • No loss of process control, optimization of assets and efficiency, no downtime or expense from calibration
  • Adaptive signal processing algorithms optimize performance, ensuring accurate measurements even in challenging flow conditions.
  • Clear display interface and LCD display with alarm function, easy to operate and debug
  • Utilize transit-time ultrasonic technology so as to realize bidirectional flow measurement by precisely measuring the time it takes for ultrasonic signals to travel upstream and downstream
  • Leverage the data logging capabilities to analyze historical flow patterns to make system optimization.
  • Built-in keypad and simple menu system for fast and easy programming of pipe diameter, pipe material, liquid type, and measurement units.

 

Principle

  • Introduction to TVT

The Transit-Time Ultrasonic Flow Meter, also known as Time-of-Flight (TVT) ultrasonic flow meter, is a non-intrusive flow measurement technology widely used for clean liquid applications. It operates on the principle of measuring the time difference between ultrasonic signals transmitted in the direction of flow and against the flow direction.

ST501 Water Treatment System Featuring Non Contact Clamp On Ultrasonic Flowmeter to Ensure No Downtime or Calibration Expense 0

The device has a pair (or more) of ultrasonic transducers installed on the exterior of the pipe (clamp-on) or inserted in-line. One transducer sends an ultrasonic pulse downstream with the flow, while the other sends it upstream, against the flow. Since the fluid's movement affects the transit time of the ultrasound, the time difference between the two signals is directly proportional to the flow velocity.

 

 

Product Dimension

Transmitter
ST501 Water Treatment System Featuring Non Contact Clamp On Ultrasonic Flowmeter to Ensure No Downtime or Calibration Expense 1
Transducer
ST501 Water Treatment System Featuring Non Contact Clamp On Ultrasonic Flowmeter to Ensure No Downtime or Calibration Expense 2

 

 

Wiring Instructions

Open the cover can be found at the right lower side, connect to DC power terminal.
As per wiring diagram to connect:
RTD input (only for Energy Model), RS485, 4-20mA, Transducer (Upstream transducer, Downstream transducer), Relay Output, OCT Output.
For double-shielded transducer cable: "+" on the blue wire, "-" on the white wire and "shield" on the shield.

ST501 Water Treatment System Featuring Non Contact Clamp On Ultrasonic Flowmeter to Ensure No Downtime or Calibration Expense 3

 

 

Communication and Output Functions

ST501 Water Treatment System Featuring Non Contact Clamp On Ultrasonic Flowmeter to Ensure No Downtime or Calibration Expense 4

The ST501 Fixed Ultrasonic Flow Meter is equipped with multiple communication and output options to ensure seamless integration into various industrial control systems. These outputs enable real-time data acquisition, remote monitoring, and control of flow-related processes.

 

Summary of Output Capabilities

Output Type Function Application Examples
RS485(Modbus) Digital communication Remote monitoring, SCADA, system integration
4-20mA Analog output PLC input, process feedback, DCS systems
OCT Pulse Flow totalization output Batch controllers, energy meters, flow loggers
Relay Alarm/ control output Trigger alarmscontrol valves/ pumps, flow safety protection

 

 

Specifications

Performance specifications
Velocity range 0 ~ ±16ft/s (0 ~ ±5m/s)
Accuracy ±1.0%
Pipe size Clamp-on: 1’’~48’’ (25mm~1200mm)
Fluid Sea Water, Kerosene, Gasoline, Oil, Alcohol, ect
Pipe material PVC, Carbon Steel, Stainless Steel, ect
Function specifications
Optional Outputs OCT Pulse output: 0~5000Hz.
Analog output: 4~20mA, max load 750Ω.
Communication interface RS485
Power supply 24V DC/1A
Keypad 16(4×4) key with tactile action
Display 20×2 lattice alphanumeric, back lit LCD.
Temperature Transmitter: 32℉~140℉ (0℃~60℃)
Transducer: 32℉~140℉ (0℃~60℃)
Humidity Up to 99% RH, non-condensing
Physical specifications
Transmitter Aluminum Alloy, IP65.
Transducer Encapsulated design, IP68.
Transducer cable Standard cable length: 33ft (10m).
Weight

Transmitter: approximately 0.7kg;

Transducer: approximately 0.4kg

 

 

 

 

 

محصولات مشابه
IP68 هيدرولوژيک کليمپ بر روي فلک متر فوق صوتي PVC ویدیو
اندازه گیری فلومتر فوق صوتی کلیپ خارجی ST501 ویدیو
PH301 اندازه گیری آب در زمان عبور از فلز ویدیو
بهترین قیمت رو بدست بیار