logo
محصولات
محصولات
خونه > محصولات > اندازه گيري جريان فوق صوتي > ST501 Insertion Ultrasonic Flowmeter Utilizing Transit Time Method for Optimized Asset Efficiency and No Process Control Loss

ST501 Insertion Ultrasonic Flowmeter Utilizing Transit Time Method for Optimized Asset Efficiency and No Process Control Loss

جزئیات محصول

محل منبع: شنژن

نام تجاری: Flo-Instru

گواهی: CE; ISO9001

شماره مدل: ST501

شرایط پرداخت و حمل و نقل

مقدار حداقل تعداد سفارش: 1

جزئیات بسته بندی: بسته بندی معمولی

زمان تحویل: 3-5 روز کاری

شرایط پرداخت: T/T

بهترین قیمت رو بدست بیار
برجسته کردن:

ST501 insertion ultrasonic flowmeter,transit time ultrasonic flowmeter,insertion flowmeter with no process loss

,

transit time ultrasonic flowmeter

,

insertion flowmeter with no process loss

اندازه لوله:
DN25-DN1200
مایع:
آب ، آب دریا ، روغن ، الکل ...
ماده لوله:
پی وی سی ، فولاد کربن ، استیل ضد زنگ ...
محدوده سرعت:
0.03 ~ 16ft/s (0.01~~5m/s)
تکرارپذیری:
0.3 ٪
منبع تغذیه:
24 ولت DC
نوع مبدل ها:
مبدل درج ، دمای کار: -40 ℉ ~ +176 ℉ (-40 ℃ ~ +80 ℃)
نمایش:
20*2 ، Alphanumeric ، LCD با نور پس زمینه
خروجی:
4-20mA ، خروجی پالس OCT ، خروجی رله ، RS-232 / RS-485 ، RTD Temp. ورودی
محفظه فرستنده:
IP65 ، محفظه ماشین آلومینیوم مرده ، CNC ماشینکاری شده
خطی بودن:
1.0٪
ارتباط:
RS485
صفحه کلید:
16 کلیدهای لمسی سبک
اندازه لوله:
DN25-DN1200
مایع:
آب ، آب دریا ، روغن ، الکل ...
ماده لوله:
پی وی سی ، فولاد کربن ، استیل ضد زنگ ...
محدوده سرعت:
0.03 ~ 16ft/s (0.01~~5m/s)
تکرارپذیری:
0.3 ٪
منبع تغذیه:
24 ولت DC
نوع مبدل ها:
مبدل درج ، دمای کار: -40 ℉ ~ +176 ℉ (-40 ℃ ~ +80 ℃)
نمایش:
20*2 ، Alphanumeric ، LCD با نور پس زمینه
خروجی:
4-20mA ، خروجی پالس OCT ، خروجی رله ، RS-232 / RS-485 ، RTD Temp. ورودی
محفظه فرستنده:
IP65 ، محفظه ماشین آلومینیوم مرده ، CNC ماشینکاری شده
خطی بودن:
1.0٪
ارتباط:
RS485
صفحه کلید:
16 کلیدهای لمسی سبک
ST501 Insertion Ultrasonic Flowmeter Utilizing Transit Time Method for Optimized Asset Efficiency and No Process Control Loss

ST501 Insertion Type Ultrasonic Flowmeter

Ultrasonic flow meters that use transit-time methods to measure flow.

 

Introduction

ST501 Ultrasonic flow meter uses the most reliable digital signal processing technology, transmitting flow measurement for a wide range of liquid and pipe size with high accuracy and reliability. Combined the outstanding performance transducer with higher industrial level material, Flo-Instruments can have long time work without any worries.

Clear menu display selections make use of instruments very convenient. The IP68 transducer is more suitable for applying in harsh environments such as humidity and immersion. Simple interface makes it very convenient to operate.

The ST501 ultrasonic flowmeter is based on Transit-Time technology, which has high measurement accuracy. Insertion transducer refers to inserting the transducer into the inside of the pipeline for flow measurement. It can accurately measure the flow rate and flow velocity inside the liquid pipeline. The advantage of the insertion transducer is that it can keep the outer surface of the pipe flat, thereby reducing pressure loss, and has high reliability and measurement accuracy.

 

Benefits

  • Measures the actual flow and total consumption ofvarious liquids
  • No loss of process control, optimization of assets and efficiency, no downtime or expense from calibration
  • Adaptive signal processing algorithms optimize performance, ensuring accurate measurements even in challenging flow conditions.
  • Clear display interface and LCD display with alarm function, easy to operate and debug
  • Utilize transit-time ultrasonic technology so as to realize bidirectional flow measurement by precisely measuring the time it takes for ultrasonic signals to travel upstream and downstream
  • Leverage the data logging capabilities to analyze historical flow patterns to make system optimization.
  • Built-in keypad and simple menu system for fast and easy programming of pipe diameter, pipe material, liquid type, and measurement units.

Flo-Instruments ST501 ultrasonic flowmeter offers high-accurate and repeatable flow measurement for liquids at an economical price. It is made of strong metal case. Combined the outstanding performance transducer with high industrial grade material, it's ideal for pipes size from 1''(25mm) up to 48''(1200mm) in diameter. Insertion transducer refers to inserting the transducer into the inside of the pipeline for flow measurement. It can accurately measure the flow rate and flow velocity inside the liquid pipeline. The advantage of the insertion transducer is that it can keep the outer surface of the pipe flat, thereby reducing pressure loss, and has high reliability and measurement accuracy.

 

Principle

  • Introduction to TVT

TVT(Transit-Time Vortex) technology represents a cutting-edge approach to ultrasonic flow measurement, combining the principles of transit-time ultrasonics with the capability to harness the vortex shedding phenomenon, delivering unparalleled accuracy and versatility in ultrasonic flow meters. This innovative integration technology enhances the accuracy, versatility, and performance of ultrasonic flow meters, making them well-suited for a wide range of applications across various industries and is a valuable solution for industries requiring precise flow measurements in varying flow conditions.

 

  • Enhanced Accuracy in Turbulent Flows:

TVT technology excels in applications where fluid flow conditions vary between laminar and turbulent. The incorporation of vortex shedding data enhances accuracy in challenging flow environments.

  • Versatility in Fluid Types:

TVT technology is versatile and suitable for a wide range of fluid types, including liquids with varying viscosities and densities.

 

 

Applications

Insertion type ultrasonic flowmeters are mainly used to measure volume flow in conductive liquids and slurry in closed pipes. Including acid, alkali, salt and other highly corrosive liquids. Insertion type ultrasonic flowmeters are widely used in petroleum, chemical, metallurgy, textile, food, pharmaceutical, paper-making and other industries, as well as environmental protection, municipal management, water conservancy construction and other fields.

 

Specifications

Performance specifications
Velocity range 0.03 ~ ±16ft/s (0.01 ~ ±5m/s)
Accuracy ±1.0%
Pipe size 1’’~48’’ (25mm~1200mm)
Repeatability 0.3% of measured value
Linerarity ±1.0%
Fluid Water, Sea water, Oil, Alcohol...
Pipe material PVC, stainless steel, carbon steel, copper...
Function specifications
Communication & Outputs Communication: ModBus RS485
Analog output: 4~20mA, max load 750Ω.
Pulse output: 0~9999Hz, OCT, (min. and max. frequency is adjustable)
Relay output: max 1Hz(1A@125V AC or 2A@30V DC)
Flow Unit Cubic Meters(m³), Liters(l), USA Gallons(gal). The factory default unit is m3/h.
Time Unit /Day/Hour, /Min, /Sec.
Power supply 24V DC/1A@ max
Keypad 16(4×4) key with tactile action
Display 20×2 lattice alphanumeric, back lit LCD.
Temperature Transmitter: 32℉~140℉ (0℃~60℃)
Transducer: -40℉~176℉ (-40℃~80℃)
Humidity Up to 99% RH, non-condensing
Physical specifications
Transmitter Aluminum alloy, IP65.
Transducer Encapsulated design, IP68.
Transducer cable Standard cable length: 33ft (10m).
Weight

Transmitter: approximately 0.7kg;

Transducer: approximately 0.4kg

 

 

 

Product Dimension

 

Transmitter
ST501 Insertion Ultrasonic Flowmeter Utilizing Transit Time Method for Optimized Asset Efficiency and No Process Control Loss 0
Transducer
ST501 Insertion Ultrasonic Flowmeter Utilizing Transit Time Method for Optimized Asset Efficiency and No Process Control Loss 1

 

 

Product Display

ST501 Insertion Ultrasonic Flowmeter Utilizing Transit Time Method for Optimized Asset Efficiency and No Process Control Loss 2

 

 

 

 

Communication and Output Functions

ST501 Insertion Ultrasonic Flowmeter Utilizing Transit Time Method for Optimized Asset Efficiency and No Process Control Loss 3

 

The ST501 Fixed Ultrasonic Flow Meter is equipped with multiple communication and output options to ensure seamless integration into various industrial control systems. These outputs enable real-time data acquisition, remote monitoring, and control of flow-related processes.

ST501 Insertion Ultrasonic Flowmeter Utilizing Transit Time Method for Optimized Asset Efficiency and No Process Control Loss 4

 

 

Summary of Output Capabilities

Output Type Function Application Examples
RS485(Modbus) Digital communication Remote monitoring, SCADA, system integration
4-20mA Analog output PLC input, process feedback, DCS systems
OCT Pulse Flow totalization output Batch controllers, energy meters, flow loggers
Relay Alarm/control output Trigger alarmscontrol valves/pumps, flow safety protection

 

 

Installation Methods & Wiring Diagram

ST501 Insertion Ultrasonic Flowmeter Utilizing Transit Time Method for Optimized Asset Efficiency and No Process Control Loss 5